16. Winterizing a Sprinkler System
You can pay the irrigation company to blow out your sprinkler system every fall, or you can use your air compressor and do it yourself. You just have to be careful not to leave any water in the line or it might freeze over the winter and burst a pipe.
Also be aware that even the largest home compressor isn’t powerful enough to blow out the entire system at once, so you’ll probably have to blow it out zone by zone. If you’re into number crunching and you have the original irrigation layout showing the gallons per minute (gpm) of each sprinkler head, just divide the total gpm of each zone by 7.5. That’ll give you the cubic feet per minute (cfm) your compressor needs to blow out the zone.
Otherwise, just rent a 10-cfm compressor and hose from your local tool rental center. Set the compressor air pressure regulator to a maximum of 80 psi for rigid PVC pipe systems, or 50 psi for flexible black polyethylene pipe. Then turn off the water supply and set the system timer to open just one zone. Next, open the manual drain valve at the end of that zone (if equipped). Close off both valves on the backflow preventer. Then remove the plug on the blow-out port and screw in a quick-connect hose adapter. Snap on the air hose and connect the other end to the compressor.
Then blow out the line. The heads should pop up and spit out water. Disconnect the hose as soon as they run dry. Don’t overdo the blow-out — without water cooling the plastic gears, they can melt in less than a minute. So move on to the next zone and allow the heads to cool. Then go back and blow out each zone a second time.

17. Bleeding a Hot Water Radiator
If some fins of your hot water radiator stay cold while others get hot, don’t despair. Your radiator has some trapped air, and getting rid of it is simple. At the top of your radiator, look for a small valve like the one shown. Use a radiator key, 1/4-in. 12-point socket, or a flat screwdriver (depending on your valve type) and slowly turn the valve counterclockwise until water starts dripping out. This will release trapped air and let hot water into the cold fins. While you’re at it, you should repeat the process with your other radiators.
Bleeding the radiators will lower the pressure in your system, so you might have to slowly add water to increase the pressure. Do this by opening, then closing, the valve on the water pipe above the boiler. In fact, you may need to add water while bleeding the radiator in order to purge the air from the system. This is where a helper will save on trips up and down the stairs. If you’re unfamiliar with your system, call a pro.
How much pressure you need depends on how high the water has to rise. The basic rule is 1 lb. of pressure for every 2 ft. of rise. Your gauge may read in pounds, feet or both. A basic two-story house, with the boiler and expansion tank in the basement, needs 12 to 15 lbs., or 25 to 30 ft., of pressure.

18. Clear a Steam Radiator Vent
Don’t confuse a hot water system with a steam system. Steam radiators have an air vent, like the one shown, about halfway down the side. Unfortunately, many of these air vents get painted over, plugging the air hole. Clear the air hole in the top of the vent with a small wire or sewing needle. If you’re still worried about the air vents working, consult a hot water/steam heat specialist. Replacing these vents costs $16 to $20 per radiator.